Hardware modifications to Rev 1.1

C58 is the wrong way round

The tantalum electrolytic capacitor C58 is already fitted the wrong way round in the circuit diagram. The error was noticed by coincidence by DG1YFE, although there have been no problems in practise to date. The problem will be solved with Rev 1.2 of the production series.

Further modifications

see Rev12Mods